SOURce Commands
Copyright © ITECH Electronic Co., Ltd. 36
300V
VOLTage:LIMit:HIGH? //Query the voltage upper limit
[SOURce:]VOLTage:LIMit:LOW <NRf+> [,CH1|CH2|CH3]
This command sets and query the lower limit of RMS voltage.
Note: the second parameter is optional and only valid in multi-channel mode.
Syntax:
VOLTage:LIMit:LOW <NRf+> [,CH1|CH2|CH3]
Arguments:
MAXimum|MINimum|DEFault
Query syntax:
VOLTage:LIMit:LOW? [CH1|CH2|CH3],[MAXimum|MINimum|DEFault]
Returns:
MAXimum|MINimum|DEFault
Example:
VOLTage:LIMit:LOW -11 //set the lower voltage to -11V
VOLTage:LIMit:LOW -11,1 //set lower voltage of CH1 to -11V
VOLTage:LIMit:LOW? //Query the lower volage setting
[SOURce:]PVOLtage[:LEVel][:IMMediate][:AMPLitude][:
AC] <phase>,<NRf+>
It is used to set and query the AC voltage of a certain phase in normal mode.
phase: phase identification.
NRf+: AC voltage setting value.
Syntax:
PVOLtage[:LEVel][:IMMediate][:AMPLitude][:AC] <phase>,<NRf+>
Arguments:
A|B|C
Query syntax:
PVOLtage[:LEVel][:IMMediate][:AMPLitude][:AC]? <phase>, [MAXimum|
MINimum|DEFault]
Returns:
A|B|C,<NRf+>

Table of Contents

Other manuals for ITech IT7900 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ITech IT7900 Series and is the answer not in the manual?

ITech IT7900 Series Specifications

General IconGeneral
BrandITech
ModelIT7900 Series
CategoryPower Supply
LanguageEnglish

Related product manuals