ISLand Subsystem
Copyright © ITECH Electronic Co., Ltd. 132
Example
ISLand:RESistance:LEVel 100
ISLand:RESistancel:LEVel?
ISLand:INDucatance:LEVel <NRf+>[,A|B|C]
This command is used to set the inductance value of the RLC analog load.
Syntax
ISLand:INDucatance:LEVel <NRf+>[,A|B|C]
Arguments
<NRf+>
Query syntax
ISLand:INDucatance:LEVel? [A|B|C]
Returns
MINimum|MAXimum|DEFault
Example
ISLand:INDucatance:LEVel 100
ISLand:INDucatance:LEVel?
ISLand:PHASe:LEVel <NRf+>[,A|B|C]
This command is used to set the island simulation start phase Angle.
Syntax
ISLand:PHASe:LEVel <NRf+>[,A|B|C]
Arguments
<NRf+>
Query syntax
ISLand:PHASe:LEVel? [A|B|C]
Returns
MINimum|MAXimum|DEFault
Example
ISLand:PHASe:LEVel 90 //start at 90 degree
ISLand:PHASe:LEVel?
ISLand:CAP:LEVel <NRf+>[,A|B|C]
This command is used to set the capacitance value for island simulation.