show chassis environment
user@host > show chassis environment
Class Item Status Measurement
Temp Routing Engine OK 64 degrees C / 147 degrees F
Routing Engine CPU Absent
Power Power Supply 0 OK
show chassis fpc
user@host >show chassis fpc
Temp CPU Utilization (%) Memory Utilization (%)
Slot State (C) Total Interrupt DRAM (MB) Heap Buffer
0 Online -------------------- CPU less FPC --------------------
1 Online -------------------- CPU less FPC --------------------
show chassis alarms
user@host >show chassis alarms
No alarms currently active
Related
Documentation
Monitoring the SRX110 Services Gateway Using Chassis Alarm Conditions on page 142•
• Monitoring the SRX110 Services Gateway Components Using LEDs on page 140
• Monitoring the SRX110 Services Gateway Power System on page 144
• Maintaining the SRX110 Services Gateway Hardware Components on page 135
Monitoring the SRX110 Services Gateway Components Using LEDs
You can monitor the chassis condition by using the LEDs. Table 47 on page 140 lists the
LEDs, their condition, the possible causes and corrective actions.
Table 47: Component LEDs on the Services Gateway
Possible Causes and
Corrective ActionsMeaningStateLED
Normal condition. No action
is required.
Indicates that the device is
functioning normally.
GreenStatus LED
Normal condition. No action
is required.
•
The device is starting up.
•
The Reset Config button
is pressed.
Amber
Contact the Juniper
Networks Technical
Assistance Center (JTAC).
See “Juniper Networks
Technical Assistance
Center” on page 147.
Indicates an error in the
device.
Red
Copyright © 2012, Juniper Networks, Inc.140