Inspecting with the Edge Position Inspection Item
FQ2 User’s Manual
4
Setting Up Inspections
121
Step 2 Teaching
Teaching means to store the region and the edge position in the region as reference data for the measurement.
[Inspect] − [Inspection] − [Add item.] − [Edge Position] − [Settings] Tab Page
The following data is stored as basic measurement data.
Step 3 Adjusting Judgement Parameters
[Inspect] − [Inspection] − [Add item.] − [Edge Position] − [Settings] Tab Page
1 Press [Teach].
2 Place the object that is to be used as the measure-
ment reference in front of the camera.
3 Move the rectangle to the location to be measured.
4 Press [OK].
5 Press [TEACH] on the lower right of the display.
The basic settings will be registered when teaching has
been completed.
6 Press [Back] to end teaching.
Changing the measurement region: p. 102
Item Parameter Description
Reference data
Reference position X The reference coordinates (X, Y) of the position are set automatically.
Reference position Y
1 Press [Judgement].
2 Press the parameters and set the range that is to be
judged as OK.
The measurement value is displayed next to the param-
eter name. Continuous measurements will be performed
for the images that are displayed.
3 Press [OK] to enter the value.
Parameter Setting Description
Position X Range: −99,999.9999 to 99,999.9999
Defaults: Lower limit: −99,999.9999, Upper limit: 99,999.9999
Adjust the upper and lower limits of edge
position X for an OK judgement.
Position Y Range: −99,999.9999 to 99,999.9999
Defaults: Lower limit: −99,999.9999, Upper limit: 99,999.9999
Adjust the upper and lower limits of edge
position Y for an OK judgement.
• You can change the output form for each measurement value to one of the following settings.
Press
[] − [Result type] on the right of the display.
Absolute value (default): The measured coordinates are output as absolute values.
Relative value: The difference from the reference value is output.
Moves the end point
of the measurement
region.
The arrow in the middle shows the
direction for detecting an edge.
Changes the width
of the measurement
region.
Moves the starting
point of the
measurement region.
Drag to move
the region.
Blue for OK. Red for NG.
Lower limit
Upper limit
You can change the parameters for judgement conditions on the
Display Settings Display. Press
[] − [Display setting] on the right
of the display to switch to the Display Settings Display.