EasyManuals Logo
Home>Omron>Digital Camera>fq2

Omron fq2 User Manual

Omron fq2
516 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #131 background imageLoading...
Page #131 background image
Inspecting with the Edge Width Inspection Item
FQ2 User’s Manual
4
Setting Up Inspections
129
Changing Edge Detection Conditions (Sensors with Monochrome Cameras Only)
You can change the measurement conditions for Sensors with Monochrome Cameras. Change the [Density
change] and [Measurement method] parameters.
p. 122
Reflect in Total Judgement
You can specify whether to reflect the judgement results of an inspection item in the overall judgement. (The
default is to reflect them.)
[Inspect] − [Inspection] − [Add item.] − [Edge Width] − [Details] Tab Page − [Output parameter]
Unstable Edge Width Results (Sensors with Color Cameras)
If the measurement result is not stable, adjust the [Edge level], [Noise level], and [Set color.] parameters.
p. 122
Increasing Edge Width Processing Speed
Make the measurement region smaller to reduce the processing time.
Changing the measurement region: p. 102
Measurement Data That Can Be Used for External Outputs and Calculations
The following values can be output to external devices or used in calculations as measurement data.
4-13 Calculations and Judgements Using Inspection Item Data: p. 155
• You can change the output form for each measurement value to one of the following settings.
Press
[] − [Result type] on the right of the display.
Absolute value (default): The measured edge width is output.
Relative value: The difference from the reference value is output.
Ratio: The percentage of the reference value is output.
Expression text string Data name Description Data range
JG Judgement This is the judgement result. −2: No judgement (not measured),
0: Judgement is OK,
−1: Judgement is NG,
−13: Teaching not performed error,
−14: Figure not registered error,
−15: Out of range error
W Edge width Edge width 0 to 99999.9999
SW Ref. edge width (reference
edge width)
This is the reference edge width from
when the model was registered.
0 to 99999.9999
DF D. edge width (difference in
edge width)
This is the difference between the ref-
erence edge width and the measured
edge width.
0 to 99999.9999