External Reference Parameters
454
FQ2 User’s Manual
Sensitive Search
External
refer-
ence
number
Category Data name Setting/Acqui-
sition
Data range Default Expres-
sion text
string
Logged data/
Judgement
parameter
0 Mea-
sure-
ment
result
Judgement Acquisition
only
−2: No judgement (not
measured),
0: Judgement is OK,
−1: Judgement is NG,
−13: Teaching not per-
formed error,
−14: Figure not registered
error,
−15: Out of range error
−2 JG Logged data
5 Correlation Acquisition
only
0 to 100 0 CR Logged data
6 Deviation Acquisition
only
Color Camera: 0.000 to
219.9705
Monochrome Camera:
0.000 to 127.000
0 DV Logged data
7 Measurement position
X (search center posi-
tion)
Acquisition
only
−99,999.9999 to
99,999.9999
0 X Logged data
8 Measurement position
Y (search center posi-
tion)
Acquisition
only
−99,999.9999 to
99,999.9999
0 Y Logged data
9 Angle Acquisition
only
−180 to 180 0 TH Logged data
10 Detection X Acquisition
only
−99,999.9999 to
99,999.9999
0 RX Logged data
11 Detection Y Acquisition
only
−99,999.9999 to
99,999.9999
0 RY Logged data
12 Reference position X Acquisition
only
−99,999.9999 to
99,999.9999
0 SX Logged data
13 Reference position Y Acquisition
only
−99,999.9999 to
99,999.9999
0 SY Logged data
14 Reference angle Acquisition
only
−180 to 180 0 ST Logged data
15 NG sub-region Acquisition
only
0 to 100 0 CT Logged data
16 Sub-region number Acquisition
only
0 to 99 0 AN Logged data
17 Sub-region number (X) Acquisition
only
0 to 9 0 ANX Logged data
18 Sub-region number (Y) Acquisition
only
0 to 9 0 ANY Logged data
19 Measurement position
X (sub-region)
Acquisition
only
−99,999.9999 to
99,999.9999
0 DX Logged data
20 Measurement position
Y (sub-
region
)
Acquisition
only
−99,999.9999 to
99,999.9999
0 DY Logged data
103 Output
parame-
ter
Reflect Setting/Acqui-
sition
0: Yes, 1: No 0 --- ---