Controlling Operation and Outputting Data with TCP No-protocol Communications
352
FQ2 User’s Manual
Setting the Data To Output Automatically after Measurements
You can set the data to output automatically after measurements. (You can set up to 32 data items.)
Data That Can Be Output
You can output up to 32 data items (data 0 to data 31).
The measurement data from inspection items that can be output and the calculation results from the
expression settings can be output. For data that can be output, refer to the Measurement Data That Can Be
Used for External Outputs and Calculations for each inspection item.
Assigning Inspection Results to Output Data
You can individually assign the parameters of the inspection items to output data (data 0 to data 31).
The following procedure shows how to assign the measured position X of [0. Search] to data 0 for a binary
output.
[In/Out] − [I/O setting] − [Output data setting] − [Link data output] − [Output data set]
1 Press [0. Data 0].
2 Press [Data setting].
3 Press [I0. Search].
4 Press [Position X X].
5 If the inspection item allows multi-point output,
press the number ([0] to [30]) of the inspection result
for which to output the data from the list of inspec-
tion results.
To register something to data 1 and higher, repeat
this process.
The settings will be enabled after you restart the Sen-
sor.