4
Setting Up Inspections
Inspecting with the Edge Width Inspection Item
FQ2 User’s Manual
127
4-8 Inspecting with the Edge Width Inspection Item
Edge Width Inspection Item
This inspection item is used to measure dimensions. Places where the color changes greatly are called edges.
The distance between two edges is called the edge width.
Setup Procedure for Edge Width Inspection Item
Step 1 Selecting the Inspection Item
[Inspect] − [Inspection]
1 Press an unused inspection item number and press
[Add item.].
2 Press [Edge Width].
Registering inspection items: p. 93
Drag the arrow at the bottom of the menu upward to display all of the inspection items.
OK NG
Color of edge to be found
Measurement region
Edges are searched from
two directions and the
distance is calculated.
Sample Settings Sample Measurement