Inspecting with the Edge Width Inspection Item
128
FQ2 User’s Manual
Step 2 Teaching
Teaching means to store the region and the edge width in the region as reference data for the measurement.
[Inspect] − [Inspection] − [Add item.] − [Edge Width] − [Settings] Tab Page
The following data is stored as the measurement reference.
Step 3 Adjusting the Judgement Parameters
[Inspect] − [Inspection] − [Add item.] − [Edge Width] − [Settings] Tab Page
1 Press [Teach].
2 Place the object that is to be used as the measure-
ment reference in front of the camera.
3 Move the rectangle to the location to be measured.
4 Press [OK].
5 Press [TEACH] on the lower right of the display.
The basic settings will be registered when teaching has
been completed.
6 Press [Back] to end teaching.
Changing the measurement region: p. 102
Item Parameter Description
Reference data Reference width The reference edge width is set automatically.
1 Press [Judgement].
2 Set the D. Width range for an OK judgement.
Continuous measurements will be performed for the im-
ages that are displayed. The measured value is dis-
played beside the parameter name.
3 Press [OK] to enter the value.
Item Parameter Setting Description
Judgement parameters Edge width (edge in
width)
When the result type is set to relative
values:
Range: −99,999.9999 or 99,999.999
Default: Upper limit: 99,999.9999,
Lower limit: −99,999.9999
When the result type is set to ratios:
Range: 0.000 to 999.9999(%)
Default: Upper limit: 999.9999, Lower
limit: 0.000
Set the upper and lower limits of the
reference width for an OK judgement.
The middle arrow is the
direction for detecting an edge.
Moves the end point
of the measurement
region.
Changes the width
of the measurement
region.
Moves the starting point
of the measurement
region.
Drag to move
the region.
Blue for OK. Red for NG.
Upper limit
Lower limit
You can change the parameters for judgement conditions on the
Display Settings Display. Press
[] − [Display setting] on the right
of the display to switch to the Display Settings Display.
Note