A-83
Appendices
CP2E CPU Unit Software User’s Manual(W614)
A-2 Auxiliary Area Allocations by Address
App
A-2-2 Read/Write Words
A512
to
A513
--- Power Interruption
Time
These words contain the time at which
the power was interrupted. The con-
tents are updated every time that the
power is interrupted. The data is
stored in BCD.
A512.00 to A512.07: Second (00 to
59)
A512.08 to A512.15: Minute (00 to 59)
A513.00 to A513.07: Hour (00 to 23)
A513.08 to A513.15: Day of month (01
to 31)
Note 1 These words are not cleared
at startup.
2 In an Eîš…îš…-type CPU Unit or
when time alignment cannot
be executed with an
N/Sîš…îš…-type CPU Unit, the
data will be for 1:01.01 on
Sunday January 1, 2001.
See Function col-
umn.
Retained Retained Written at
power
interruption.
A514 --- Number of Power
Interruptions
Contains the number of times that
power has been interrupted since the
power was first turned ON. The data is
stored in binary. To reset this value,
overwrite the current value with 0000.
0000 to FFFF hex Retained Retained Refreshed
when power is
turned ON.
A515
to
A517
--- Operation Start Time The time that operation started as a
result of changing the operating mode
to RUN or MONITOR mode is stored
here in BCD.
A515.00 to A515.07: Seconds (00 to
59)
A515.08 to A515.15: Minutes (00 to
59)
A516.00 to A516.07: Hour (00 to 23)
A516.08 to A516.15: Day of month (01
to 31)
A517.00 to A517.07: Month (01 to 12)
A517.08 to A517.15: Year (00 to 99)
Note 1 The previous start time is
stored after turning ON the
power supply until operation is
started.
2 In an Eîš…îš…-type CPU Unit or
when time alignment cannot
be executed with an
N/Sîš…îš…-type CPU Unit, the
data will be for 1:01.01 on
Sunday January 1, 2001.
See Function col-
umn.
Retained Retained See Function
column.
Address
Name Function Settings
Status
after
mode
change
Status at
startup
Write
timing
Related
flags,
settings
Words Bits

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron SYSMAC CP2E-E D Series and is the answer not in the manual?

Omron SYSMAC CP2E-E D Series Specifications

General IconGeneral
BrandOmron
ModelSYSMAC CP2E-E D Series
CategoryComputer Hardware
LanguageEnglish

Related product manuals