Scalar i6000 Installation Guide 175
Enabling Logical Serial Number Addressing for Drives
The Physical Library dialog box enables you to set up the library to automatically assign logical serial
numbers to drives in the library. Specifically, the library assigns a logical serial number to a drive in a specific
location. This is not the serial number of the particular drive. If a drive is replaced by another drive in the
same library location, the logical serial number remains the same. From the host’s perspective, the
replacement drive is the same as the original one.
1 Log on as the service user.
2 Make sure that you are viewing the physical library. From the View menu, click the name of the physical
library.
3 Click Setup→ Physical Library.
The Physical Library dialog box appears.
The Logical SN Addressing area is available to service users only.
4 In the Logical SN Addressing area, select Enable to cause the library to automatically assign logical
serial numbers to drives. Disable is the default setting.
5 Click OK.
Proceed to Using LDAP
on page 176.

Table of Contents

Other manuals for Quantum Scalar i6000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Quantum Scalar i6000 and is the answer not in the manual?

Quantum Scalar i6000 Specifications

General IconGeneral
Form FactorRack-mountable
InterfaceFibre Channel, SAS
Product TypeTape Library
CoolingRedundant cooling fans
DimensionsVaries by configuration
WeightVaries by configuration
Operating Humidity20% to 80% non-condensing
ScalabilityScalable
Drive TypesLTO
RedundancyRedundant power supplies
ManagementWeb-based management
Tape TechnologyLTO
Supported MediaLTO Ultrium 9, LTO Ultrium 8, LTO Ultrium 7, LTO Ultrium 6
Power SupplyRedundant power supplies
Non-operating Humidity5% to 95% non-condensing

Related product manuals