Using SP Mode
D127/D128 5-12 SM
16 Hound's Tooth Check
17 Black Band (Horizontal)
18 Black Band (Vertical)
19 Checker Flag Pattern
20 Grayscale (Vertical)
21 Grayscale (Horizontal)
22 Two Beam Density Pattern
23 Full Dot Pattern
24 All White Pattern
5.2.6 MEMORY CLEAR
The machine stores the engine data in the NVRAM on the BICU, and stores the other data in the
NVRAM on the optional controller. To distinguish between the engine data and the other data, see
SP5-801-003 through 015. This service program (SP5-801) handles the controller data. The data
in the BICU NVRAM (engine data) is cleared by SP5-801-002 while the data in the controller
NVRAM (controller data) is cleared by the other programs in SP5-801 (for exceptions, see
"Exceptions" as described below).
Data NVRAM Cleared by Remarks
Engine data BICU SP5-801-002
Any data other than controller
data
Controller data Controller SP5-801-xxx
SCS, IMH, MCS, Copier
application, Fax application,
Printer application, Scanner
application, Web
service/network application,
NCS, R-Fax, DCS, UCS