6.1.3 SC CODE DESCRIPTIONS
SC6xx
No.
Definition
Symptom Possible Cause/Countermeasure
632 C
MF accounting device error 1
The machine sends a data frame.
No normal end signal returns.
This symptom happens three
times.
ï‚§ Defective or broken line
between machine and device
633 C
MF accounting device error 2
The machine is communicating
with the accounting device. The
break signal returns.
ï‚§ Defective or broken line
between machine and device
634 C
MF accounting device error 3
A backup RAM error is reported
from the accounting device.
ï‚§ Defective accounting device
controller
ï‚§ Defective battery in the
accounting device
635 C
MF accounting device error 4
A battery voltage error is reported
from the accounting device.
ï‚§ Defective accounting device
controller
ï‚§ Defective battery in the
accounting device