3.2.3OUTPUT CHECK MODE TABLE
Press the key to turn on the selected electrical component. The status of
the component is displayed on the paper length indicator.
To turn off the component, press the key again.
Program
No.
Electrical Component
0 Main Motor
1 Toner Supply Clutch
2 Pick off solenoid
3 Registration Clutch
4 Total Counter
5 Pre-transfer Lamp
6 Quenching Lamp
7 Fusing Lamp
8 Exposure Lamp (100% duty ratio)
9 Exposure Lamp (selected ID level)
10 Main Charge Corona
11 Grid Voltage
12 Transfer Charge Corona
13 Not Used
14 Separation Charge Corona
15 to 19Not Used
20 Bias Voltage for the Image Area
21 Bias Voltage for the Non-image Area
22 Main Charge Corona + Grid Voltage
23
Main Motor + PTL + Bias Voltage for
the Non-image Area + Quenching
Lamp
24 to 25Not Used
26 Roll Feeder Dehumidity Heaters
27 Roll Feeder Cutter Motor
*Note
28 Roller Feeder Paper Feed Motor
NOTE:The cutter unit continuously moves between the left and right cutter
switches. The number of the movement (0~9999) is displayed on the
paper length indicator.
SM 4-29 A163