12. Set the multimeter range at dc 200 µA.
13. Select SP mode No. --16.
14. Press the key to turn on the separation corona.
15. Check the multimeter. Press the key and then change the current
using and keys so that the dc separation current is dc --20
± 2.5 µA.
16. If the voltage is within that of the standard voltage, press the key.
17. Select SP mode No. --17.
18. Press the key to turn on the separation corona.
19. Check the multimeter. Press the key and then change the current
using and keys so that the dc separation current is dc --20
± 2.5 µA.
20. If the voltage is within that of the standard voltage, press the key.
Rev. 5/95
SM 5-25 A163