T & S CORONA UNIT
A251/A252 5-10 SM
Separation Corona Wire Replacement
1. Remove the separation corona wire [C].
2. Hook one end of the new separation corona wire on the terminal [D] of the right
endblock.
3. Hook the center part of the separation corona wire on the spring [E] of the left
endblock.
4. Set the wire on the slots [F].
5. While pushing the spring in the direction of the arrow, hook the other end [G] of
the separation corona wire on the terminal of the right endblock.
6. Make sure the wire is set on the slots [F].
Transfer Corona Wire Replacement
1. Remove the transfer corona wire [H].
2. Install the new transfer corona wire.