2-5 Before Starting Operations
Spindle Run-in (Warm-up)
In any of the following cases, perform run-in (warm-up) operation for the spindle. Failure to do so may result in unstable
spindle rotation.
When using for the rst time after purchase
After moving the machine and reinstalling it at a dierent location
After replacing the spindle unit
When using in a low-temperature environment
How to Perform Run-in (Warm-up) Operation
Carry out the following steps 1 through 4.
P. 47, “Starting and Stopping Spindle Rotation”
Step1
Speed : 5,000 rpm
Rotation time : 15 minutes
Step2
Speed : 10,000 rpm
Rotation time : 10 minutes
Step3
Speed : 15,000 rpm
Rotation time : 10 minutes
Step4
Speed : 20,000 rpm
Rotation time : 15 minutes

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Roland EGX-350 and is the answer not in the manual?

Roland EGX-350 Specifications

General IconGeneral
Drive SystemStepper motor
InterfaceUSB
Engraving Area350 x 300 mm
Engraving Area (mm)300 x 210 mm
Software Resolution (mm)0.01 mm/step
Spindle Speed7, 000 rpm
Power SupplyAC 100 - 240 V, 50/60 Hz
Acoustic Noise65 dB (A) or less (when not cutting)
Operating Temperature5 - 40 °C
Operating Humidity35 to 80% (no condensation)
External Dimensions (mm)680 x 580 x 430

Related product manuals