Operation
9.3 Faults and how to resolve them
SIMOTICS M-1FE2 built-in motors
180 Hardware Installation Manual, 04/2020, A5E50074509B AA
9.3 Faults and how to resolve them
This chapter describes possible faults and the measures to be taken to resolve them.
Precondition
Only eliminate faults and causes of faults if you are technically qualified to do so.
Possible faults and the measures to be taken to resolve them
WARNING
Danger to life as a result of protective devices being taken out of service
If protective devices are taken out of service there is a risk of serious injury or death in the
event of a fault.
Never disable protective functions or devices, even in test operation.
If there are deviations from normal operation or if faults occur, proceed initially according
to the following list.
Fault
Cause of fault (see key table)
Motor spindle does not start
A
B
E
Motor spindle starts slowly
A
C
E
F
Humming noise when starting
C
E
F
Humming noise during operation
A
C
E
F
High temperature rise during no-load
operation
D G H I
High temperature rise under load
A
C
G
H
I
High temperature rise of individual
winding sections
E F
Uneven running
J
K
Grinding sound, bearing noise L
Radial vibrations
M
N
O
Axial vibrations O
Water escaping
P
Correct the cause of the fault as specified in the remedial measures section.

Table of Contents

Other manuals for Siemens SIMOTICS Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMOTICS Series and is the answer not in the manual?

Siemens SIMOTICS Series Specifications

General IconGeneral
BrandSiemens
ModelSIMOTICS Series
CategoryEngine
LanguageEnglish

Related product manuals