7.2.6 Cable cross-section, cable outer diameter and cable variant for synchronous
versions
The values specified in the following table refer to the cable outlet of the motor.
Cable cross-sections (Cu) and outer diameter of the connecting cables
Cable cross-
section per phase
3)
in mm
2
Outer cable
diameter
in mm
Cable cross-
section per phase
3)
in mm
2
Outer cable
diameter
in mm
1FE2183-8LN☐☐-☐CC0 2 x 6 2 x 5.0 2 x 10 2 x 6.8
According to EN 46200 it can only be used in the motor spindle
Notes on using cables are provided in VDE 0298, Part 3 and Part 4
3)
For large cable cross-sections, provide an elongated hole as bushing, where necessary.
You configure further connection cables appropriate for the rated current in accordance with
EN 60204-1 depending on the routing type and the ambient temperature.