Motor components, characteristics and options
4.2 Cooling
SIMOTICS M-1FE2 built-in motors
Hardware Installation Manual, 04/2020, A5E50074509B AA
71
4.2.6 Calculation of the cooling power to be dissipated (power loss)
Table for calculating the cooling powers to be dissipated (power loss) for synchronous motors
The values specified in the following table refer to a cooling-medium temperature of 20 °C
and S1 duty.
The cooling capacities to be dissipated at maximum speed and at rated speed are listed in
the following table. Intermediate values can be linearly estimated proportional to the speed.
1FE2183-8LH☐☐-☐CC0 88.1 4200 1000 6.1 7