Connection
7.2 Electrical connection
SIMOTICS M-1FE2 built-in motors
150 Hardware Installation Manual, 04/2020, A5E50074509B AA
7.2.9.2 Overview of connections with two power units
You can operate the 1FE2 motor on two power units.
Connection overview for use of two power sections with the "SERVCOUP" OA software with VPM
Note
The following circuit app
lies only to 1FE2 with I
n
> 200
A for a parallel circuit on two booksize
Motor Modules.
Voltage limiting (VPM), only if the EMF > 820 V
Tripping unit for evaluating the PTC triplet
SMC20/SME20, encoder on the motor side, connector kits 6FX2003-0SA12, 12-pin
DRIVE-CLiQ cable, trailable or conditionally trailable
Signal line, trailable or only conditionally trailable
Conductor in the signal cable from the PTC to the tripping unit
5 Signal connector, 17 pin, external thread, Article No.: 6FX2003-0SA17
Optional mounting flange for retrofitting, Article No.: 6FX2003-7DX00
Temperature sensor (+1 Pt1000 spare)
Figure 7-6 Connection overview with OA software and VPM