VAF METER REMOVAL
1. DISCONNECT INTAKE AIR CONNECTOR
2. REMOVE AIR CLEANER CAP WITH VOLUME AIR
FLOW METER
(a) Disconnect the volume air flow meter connector.
(b) Remove the air cleaner cap with volume air flow
meter.
3. REMOVE VOLUME AIR FLOW METER
Remove the bolt, four nuts, washers, volume air flow
meter and gasket.
VAF METER INSTALLATION
1. INSTALL VOLUME AIR FLOW METER
Install the gasket, volume air flow meter, washers,
nuts and bolt. Torque the nuts and bolt.
2. INSTALL AIR CLEANER CAP WITH VAF METER
(a) Install the air cleaner cap with VAF meter to the air
cleaner case.
(b) Connect the VAF meter connector.
VAF METER INSPECTION
MEASURE RESISTANCE OF VAF METER
Using an ohmmeter, measure the resistance between
each terminal by moving the measuring plate.
HINT: Resistance between terminals E2 and Vs will
change in a wave pattern as the measuring plate
slowly opens.
Measuring plate
opening
Other than
closed position
E2 – Vs
Resistance ()
Between
terminals
20– 1,000
Fully closed
Fully closed
Fully open
20–400
E1– Fc
Infinity
Zero
–ENGINE MFI SYSTEM
EG1–195