wc_tx003229gb_FM10.fm
86
Mobile Generator
Working with Basler Controller
8.13 Changing the Pre-Crank Time Delay (Glow Plug Timer)
Requirements
Machine stopped
Start switch in REMOTE START
Note: Internal programming of the genset controller, or closed connections to a
remote start switch, may cause the machine to start unexpectedly. Be prepared for
the engine to start even with the engine start switch in the REMOTE START
position.
Background
The genset controller includes a pre-crank time delay. This is the time the glow
plugs will be on before the engine starts to crank. The factory setting is 5 seconds.
The pre-crank time delay can be changed if desired.
NOTICE: Do not set the glow plug timer to a value of more than 10. Damage to the
glow plugs may occur.
Procedure
Perform the procedure below to change the pre-crank time delay.
1. Press the right arrow button (1) to access the MAIN MENU.
2. Using the up/down arrow buttons (2, 3) highlight SETTINGS. Then, press the
right arrow button.
3. Highlight SYSTEM PARAMS. Then, press the right arrow button.
This procedure continues on the next page.