134 Technical data
Derating characteristic for 9 A models (E152A09...):
Overtemperature trips
The MicroFlex e150 contains internal temperature sensors that will cause it to trip
and disable if the temperature exceeds 80 °C (3 A model), or 75 °C (6 A and 9 A
models). This limit can be read using the TEMPERATURELIMITFATAL keyword - see
the Mint help file for details.
30
0
2
4
6
7
8
9
1
3
5
35 40 45 50 55
30
0
2
4
6
7
8
9
1
3
5
35 40 45 50 55
Ambient temperature (°C)
Three-phase AC supply
Single-phase AC supply
Natural cooling
1 m/s forced air
1 m/s forced air
Natural cooling
Rated output current (A
rms
)Rated output current (A
rms
)
Ambient temperature (°C)
Notes:
Load power factor = 0.75.
Overload limit for models E152A09... is 18 A.
1.5 m/s forced air
1.5 m/s forced air
2.5 m/s forced air
2.5 m/s forced air
3.5 m/s forced air