Technical data 137
Input power-cycling and inrush
If AC power has been removed from the MicroFlex e150, it should remain
disconnected for the specified period before it is reapplied:
This delay allows the input surge protection circuit to perform correctly, ensuring that
the inrush current (typically 1.7 A) is below the drive rated current. Power-cycling the
drive more frequently could cause high inrush current and corresponding nuisance
operation of circuit breakers or fuses. Repeated failure to observe the delay period
could reduce the lifetime of the MicroFlex e150.
Discharge period
WARNING! After AC power has been removed from the MicroFlex e150, high
voltages (greater than 50 V DC) can remain on the brake resistor connections
until the DC-bus circuitry has discharged. The high voltage can remain for the period
specified in the table below.
MicroFlex e150
current rating
Minimum power cycle delay period
(seconds)
3A 25
6A 45
9A 65
MicroFlex e150
current rating
Time for DC-bus to discharge to 50 V or less
(maximum, seconds)
3A 83
6A 166
9A 248

Table of Contents

Other manuals for ABB MicroFlex e150

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB MicroFlex e150 and is the answer not in the manual?

ABB MicroFlex e150 Specifications

General IconGeneral
BrandABB
ModelMicroFlex e150
CategoryControl Unit
LanguageEnglish

Related product manuals