aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa
Pulse Menu
Function Group
4
MOD
5
Menu Map
4
Description
This description is for the
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
Pulse Menu
softkey for swept signal
generators
with
Option 002. For the standard 002
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
Pulse Menu
softkey go to the \Pulse Menu" heading that precedes this one.
This softkey accesses the pulse mo dulation softkeys. These softkeys
engage external, internal, and scalar pulse mo dulation. They allow
you to dene the rise time, and give access to the internal menu for
dening the parameters of the internally-generated pulse mo dulation.
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
Pulse On/Off Ext
Toggles on and o the pulse mo dulation
mo de for an external pulse source.
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
Pulse On/Off Scalar
Toggles on and o the internal scalar
mo dulation mo de.
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
Pulse On/Off Int
Toggles on and o the internal pulse
mo dulation mo de.
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
Internal Menu
Gives access to the internal menu
for dening the parameters of the
internally-generated pulse mo dulation.
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
Pulse Rise Time Fast
Applies a fast rise pulse lter to both
internal and external pulse waveforms.
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
Pulse Rise Time Slow
Applies a slow rise pulse lter to b oth
internal and external pulse waveforms.
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
Pulse Rise Time Auto
Automatically applies the appropriate
lter (fast or slow) to b oth internal and
external pulse waveforms.
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
Invert Input
Inverts the pulse input logic. When
active, a +5 V input turns RF po
wer o.
Programming Codes
SCPI:
NONE, see the individual softkeys listed.
Analyzer:
NONE
See Also
4
MOD
5
, also see \Mo dulation" and \Pulse".
P-18 Operating and Programming Reference

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies 83620B and is the answer not in the manual?

Agilent Technologies 83620B Specifications

General IconGeneral
BrandAgilent Technologies
Model83620B
CategoryInverter
LanguageEnglish

Related product manuals