EasyManuals Logo
Home>Agilent Technologies>Inverter>83620B

Agilent Technologies 83620B User Manual

Agilent Technologies 83620B
496 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #399 background imageLoading...
Page #399 background image
OPTION NOT INSTALLED. The language selected and the
corresp onding rmware/hardware necessary to run that language
is not present in the swept signal generator. See Chapter 3 for
information on language selection.
DISPLAY IS NOT RESPONDING
: Can app ear on the front panel
emulator if the internal processor can not communicate with the
display prop erly. This error indicates a display failure or a display
connector problem.
DIVIDE BY ZERO EXCEPTION
: This can only b e caused by
an internal pro cessor error. Refer to Chapter 4 for instructions on
contacting a qualied service technician.
EEROM FAILED, LOST CAL
: This error indicates that the swept
signal generator has lost its calibration constants and may not meet
specications. Refer to Chapter 4 and follow the lo cal op erator's
check pro cedures. If you are a qualied service technician and this
failure o ccurs, read the Calibration Constants section in the
Agilent
Technologies 8360 B-Series Swept Signal Gener
ator/8360 L-Series
Swept CW Generator Service Guide
.
EEROM Failed !!
: This error will only o ccur if the service
adjustment menu is accessed. Specically, an attempt has b een made
to write to a test patch and EEROM failed to store the data.
ERROR: CALIBRATION FAILED !!
: This error will only o ccur if
the service adjustment menu is accessed. Sp ecically, an A14 sweep
ramp calibration has been attempted and failed. Run the sw
eep
ramp selftest. Refer to the \MENU MAPS" chapter in the
Agilent
Technologies 8360 B-Series Swept Signal Generator/8360 L-Series
Swept CW Generator Service Guide
.
ERROR - Must rst enter correction freq
: This error o ccurs when
a correction p oint does not have its corresp onding frequency entered
rst. Refer to \Creating and Applying the User Flatness Correction
Array" in Chapter 1.
ERROR: Must rst enter a List Frequency !!
: This error o ccurs
when a dwell or oset value does not have its corresp onding
frequency entered rst. Refer to \Creating and Applying the User
Flatness Correction Array" in Chapter 1.
ERROR: Power SearchFailed !!
: This error o ccurs when the ALC
is in the ALC search mo de and is unable to level to the desired
power level. Refer to Chapter 4 and follow the lo cal op erator's check
pro cedures.
ERROR: Start must be
<
Stop !!
: This error o ccurs in asso ciation
with the frequency list, auto ll, feature. If the start frequency
entered is greater than the stop frequency,you will see this error.
Correct byentering a start frequency less than the stop frequency
.
ERROR: Stop must be
>
Start !!
: This error o ccurs in asso ciation
with the frequency list, auto ll, feature. If the stop frequency
2a-2 Error Messages

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies 83620B and is the answer not in the manual?

Agilent Technologies 83620B Specifications

General IconGeneral
BrandAgilent Technologies
Model83620B
CategoryInverter
LanguageEnglish

Related product manuals