LINT2 INTERRUPT
: This can only b e caused byaninternal
pro cessor error. Refer to Chapter 4 for instructions on contacting a
qualied service technician.
LINT6 INTERRUPT
: This can only b e caused byaninternal
pro cessor error. Refer to Chapter 4 for instructions on contacting a
qualied service technician.
Number of pts must be
>
=2!!
: This error o ccurs in asso ciation
with the user p ower atness, auto ll number of points, feature. If
the number of p oints requested is less than two, you will see this
error message. Correct byentering number of p oints greater than or
equal to two.
OPTION NOT INSTALLED
: This error o ccurs when the GPIB
language switch is set to a conguration requiring a certain
rmware/hardware combination to be present in the swept signal
generator. See Chapter 3 for information on language selection and
see \Specications" for information on option available.
PRIV VIOLATION EXCEPTION
: This can only b e caused by
an internal pro cessor error. Refer to Chapter 4 for instructions on
contacting a qualied service technician.
RECALL REGISTERS LOST
: This message can app ear in
asso ciation with the security menu feature, memory clear. Also, a
weak, dead, or disconnected internal battery can cause this message.
Refer to Chapter 4 for instructions on contacting a qualied service
technician.
Selftest REQUIRES system interface OFF
: This error message
indicates that the swept signal generator is connected to a network
analyzer and can not run selftest. Correct by disconnecting the
system interface cable from the swept signal generator.
SPURIOUS INTERRUPT
: This can only b e caused byaninternal
pro cessor error. Refer to Chapter 4 for instructions on contacting a
qualied service technician.
SYSTEM CONTROLLER ON BUS
: This error message is
generated when an external controller is active on the GPIB and
the swept signal generator has attempted to act as the con
troller.
Disconnect the GPIB interface or return the swept signal generator
to LOCAL op eration and rep eat the request.
TOO MANY CORRECTION PTS REQUESTED
: This error
o ccurs in asso ciation with the user p ower atness menu. The
maximum numb er of correction points has b een reached or the
addition of the points requested will exceed the maximum. The
maximum numb er of p oints available is 801.
TOO MANY LIST POINTS REQUESTED
: This error o ccurs in
asso ciation with the frequency list menu. The maximum number of
list p oints has b een reached or the addition of the p oin
ts requested
will exceed the maximum. The maximum n
umb er of p oints available
is 801.
2a-4 Error Messages