EasyManuals Logo
Home>Coastcom>Multiplexer>D/I Mux III System

Coastcom D/I Mux III System User Manual

Coastcom D/I Mux III System
329 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #132 background imageLoading...
Page #132 background image
Chapter 4. Configuration and Operation
112
DA - Displaying Alarms
Enter DA to Display the T1 Alarm data (as depicted in Figure 4-10). The Card Slot column indicates
which card generated the alarm. The Alarm column indicates the type of alarm it generated. The Level
column shows Major, Minor, or Info alarms based on the severity of the alarm.
The Status column will display Active or Clear, based on the current status of the alarm. The Count
keeps track of the number of times the alarm cycled between clear and active states. (Note that the
count becomes incremental when the alarm goes to active status.)
] DA
10:48:55--------------- [ T1 Alarm Data ] ------------------03/08/95
Card Slot Alarm Level Status Count
------------ -------------- ----- ------ -----
LIU T1-2 RED Alarm Major Active 2
LIU T1-2 CGA Info Active 2
LIU T1-2 CLOCK Change Info Clear 1
LIU T1-2 RCVD Clk Loss Major Active 1
LIU T1-1 RED Alarm Major Active 2
LIU T1-1 CGA Info Active 2
LIU T1-1 CLOCK Change Info Clear 1
LIU T1-1 RCVD Clk Loss Major Active 2
--------------------------------------------------------------------
Figure 4-10. Displaying Alarm Data

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Coastcom D/I Mux III System and is the answer not in the manual?

Coastcom D/I Mux III System Specifications

General IconGeneral
BrandCoastcom
ModelD/I Mux III System
CategoryMultiplexer
LanguageEnglish