Chapter 4. Configuration and Operation
119
DN - Displaying the Current Working Map
Enter DN to display the current working map number (Figure 4-17).
] DN
Current Working Map: 1
Figure 4-17. Displaying the Current Working Map
DP - Displaying System Parameters
Enter DP to Display system Parameters, as shown in Figure 4-18.
] DP
09:55:03--------------- [ System Parameters ]----------------- 03/08/95
System Label : Day Of Week : Wed
System ID : 0 Alarm Report Mode : REPORTING
Shelf Size : 12 Alarm Report Bell : OFF
Comm. Mode : TERM Data Rate Jumper W1 : Disabled
Comm. Data Rate : 19200 MML Jumper W2 : Disabled
Modem Present : NO I960 MCU Present : Yes
Port Exp. Present : NO Mapping Restrictions : Enabled
CGA Release Secs : 5.0 REM Alarm : Block
DCGA Delay Secs : 2.5 TX REM Alarm Mode : FDL
Jitter Atten. UI : 28 Slip Buffer : Disabled
Figure 4-18. Displaying System Parameters