Chapter 10 TroubleshootingASDA-A2R Series
10-32 Revision December, 2014
10.5 Corrective Actions after the Alarm Occurs
:Over current
Turn DI.ARST on to clear the alarm
:Over voltage
Turn DI.ARST on to clear the alarm
:Undervoltage
The alarm can be cleared after the voltage
returns to normal.
:The magnetic field of the
motor is abnormal
The alarm can be cleared after re-power on.
:Regeneration error
Turn DI.ARST on to clear the alarm
:Overload
Turn DI.ARST on to clear the alarm
:Excessive speed deviation
Turn DI.ARST on to clear the alarm
:Abnormal pulse command
Turn DI.ARST on to clear the alarm
:Excessive deviation of
position control
Turn DI.ARST on to clear the alarm
:Encoder error
The alarm can be cleared after re-power on.
:Adjustment error
The alarm can be cleared when removing
CN1 wiring and execute auto adjustment.
:Emergency stop
The alarm can be cleared automatically after
turning DI.EMGS off
:Reverse limit error
Turn DI.ARST on or Servo Off to clear the
alarm. The alarm also can be cleared when
the motor operates backwards.
:Forward limit error
Turn DI.ARST on or Servo Off to clear the
alarm. The alarm also can be cleared when
the motor operates backwards.
:The temperature of IGBT is
abnormal
Turn DI.ARST on to clear the alarm
:Abnormal EEPROM
If the alarm occurs, then parameter reset is a
must. And re-servo on again. If it happens
during the operation, please turn DI.ARST on
to clear the alarm.
:Abnormal signal output
Turn DI.ARST on to clear the alarm
:Serial communication error
Turn DI.ARST on to clear the alarm
:Serial communication
timeout
Turn DI.ARST on to clear the alarm
:Main circuit power leak
phase
Turn DI.ARST on to clear the alarm
:Early warning for overload
Turn DI.ARST on to clear the alarm