13 CANopen Communication Card
DVP-PM Application Manual
13-26
HMI Setting
HMI functions as Master, therefore the Ethernet connection with the 2 Slaves should be set up in addition to
its IP address. To set up the connection between HMI and DVP-FPMC, please follow the procedure below:
1. Open or create a file in Screen Editor. Select Configuration from Options in menu bar.
2. In “General” window, select DOP-B10E615 as the HMI type from the drop-down list in “Standard”
column.
3. In “COM port” window, select “Ethernet” and check “Overwrite IP” in the right. Enter the IP
address of HMI.
4. Add the connections for the devices to be connected. Click “Add” and enter the Link Name for the
device. Select “Delta VP TCP/IP” in the list of Controller and click OK, the device will be created with
the Link Name.