AT commands Firmware version/information commands
Digi XBee3 Cellular LTE-M/NB-IoT Global Smart Modem User Guide
191
Firmware version/information commands
The following AT commands are firmware version/information commands.
VR (Firmware Version)
Reads the firmware version on a device.
Parameter range
0 - 0xFFFF [read-only]
Default
Set in firmware
VL (Verbose Firmware Version)
Shows detailed version information including the application build date and time.
Parameter range
N/A
Default
Set in firmware
HV (Hardware Version)
Read the device's hardware version. Use this command to distinguish between different hardware
platforms. The upper byte returns a value that is unique to each device type. The lower byte indicates
the hardware revision.
Parameter range
0 - 0xFFFF [read-only]
Default
Set in firmware
AI (Association Indication)
Reads the Association status code to monitor association progress. The following table provides the
status codes and their meanings.
Statuscode Meaning
0x00 Connected to the Internet.
0x22 Registering to cellular network.
0x23 Connecting to the Internet.
0x24 The cellular component is missing, corrupt, or otherwise in error. The cellular
component requires a new firmware image.