Digi XBee3 Cellular LTE-M/NB-IoT Global Smart Modem User Guide
204
DP (Remote Manager Phone Number)
Sets the Remote Manager phone number for the XBee device. This code must match the phone
number option in the SMSConfiguration dialog.
See Configure SMSmessaging in Remote Manager for more information.
Range
-
Default
32075
HF (Health Metrics Reporting Frequency)
Reports the time between attempts to upload metrics. The time is measured in minutes. Metrics
which cannot be collected or reported at any particular time are skipped until the next attempt.
Parameter range
N/A
Value Description
0x3c
One hour.
Default
0x3c
HM (Health Metrics)
Sets the Health Metrics to report. This is a bit-mask of values. Each bit set in the mask represents a
metric which is reported to Remote Manager.
Parameter range
N/A
Bit Description
0 Signal Strength. This is the same value as reported by the
DB command in dbM and will be reported to the
"metrics/signal_strength" Data Stream in Remote
Manager for the devices.
Default
0x0