API frames AT Command: Queue Parameter Value - 0x09
Digi XBee3 Cellular LTE-M/NB-IoT Global Smart Modem User Guide
213
AT Command: Queue Parameter Value - 0x09
Description
This frame allows you to query or set device parameters. In contrast to AT Command - 0x08, this
frame queues new parameter values and does not apply them until you issue either:
n The AT Command (0x08) frame
n The AC command
When querying parameter values, the 0x09 frame behaves identically to the 0x08 frame. The device
returns register queries immediately and not does not queue them. The response for this command is
also an AT Command Response frame (0x88).
Format
The following table provides the contents of the frame. For details on frame structure, see API frame
format.
Field
name
Field
value
Data
type Description
Frame
type
0x09 Byte
Frame ID Byte Identifies the data frame for the host to correlate with a subsequent
ACK. If set to 0, the device does not send a response.
AT
command
Byte Command name: two ASCII characters that identify the AT command.
Parameter
value
Byte If present, indicates the requested parameter value to set the given
register. If no characters are present, it queries the register.