Maintenance 4. Alarm
124 VT Rev.1
4.1 Maintenance
The recommended replacement time can be configured for the batteries, timing belts,
motors, and reduction gear units.
CAUTION
■
Manipulator and the Maintenance information.
Settings of the Maintenance are different depending on installation methods of the
firmware.
Initial installation : Maintenance is enabled.
Upgrade : Maintenance inherits the previous data.
(Disables as default)
For details for enabling or disabling the Maintenance, refer to the EPSON RC+ 7.0 User’s
Guide 5.12.2 [System Configuration] Command (Setup Menu) - [Setup]-[System
Configuration]-[Controller]-[Preferences] Page.
Maintenance is enabled at shipment.
If enabled, the Maintenance information for the timing belts, motors, and reduction gear
units will be configured automatically when the robot is configured or changed.
When the Manipulator is deleted from the configuration, the Maintenance information will
also be automatically deleted.
For details on the manipulator configuration, refer to the EPSON RC+ 7.0 User’s Guide
10.1 Setting the Robot Model.
CAUTION
■
Changing of the
manipulator
should be done carefully. The alarm setting will
be reset when the
manipulator
is changed.
If the Maintenance is enabled, the battery is automatically configured at the first
connection.