Parameter Values
The tables below list the parameter value, or value range that are specific to the camera.
The configuration parameters are defined in the Multicam Configuration window,
Operation page, Hypermotion controller section.
Configuration Parameter Value
Port RS422
Protocol Sony 9-PIN
The operational parameters are defined in the Hypermotion mode of the Remote Panel, in
the LCD secondary menu.
Operational Parameter Value Range Default Value
# Blocks 1 to 4 1
Pre-Roll from 00s00fr to 5s00fr 00s00fr
PGMSpeed 50, 100, 200, 300, 400,1000% 100
2nd Lever +/- 1000%, 0-1000% +/- 1000
Specific Behavior of Remote Panel Keys
• RECORD: The Remote does not beep if the CAM key refers to an empty block.
• RECORD: Pressing this key while the current block is recording does not send any
command to the camera.
• TAKE: This key is operational in ARM mode.
• CLEAR: This key has no effect.
Cue Points Management
• When a new ARM/REC command is issued on a block, all its cue points are cleared.
• Cue points can only be marked when working with single-block memory.
• If the Last Cue command cannot access the desired TC preroll, the player remains on
the current cue point.
• If the Last Cue command refers to a TC that does not exist anymore, the player
jumps to the beginning of the current memory block.