TAP Series Switch Command Line Reference
230
Related Commands
show sflow
15.4 sflow counter interval
Use this command to configure sFlow polling-interval for counter sample.
Use the no form of this command to restore the default value.
Command Syntax
sflow counter interval INTERVAL_VAL
no sflow counter interval
INTERVAL_VAL
Interval value in second
Command Mode
Global Configuration
Default
20 seconds
Usage
Use this command to set sFlow polling-interval for counter sample. Use the no parameter
with this command to restore to the default value. Default interval value is 20 seconds.
Examples
This example shows how to set sFlow polling-interval to 10 second:
Switch(config)# sflow counter interval 10
This example shows how to set sFlow polling-interval to default value:
Switch(config)# no sflow counter interval