TAP Series Switch Command Line Reference
show stm prefer next
Use this command to specify the system temperature monitor threshold.
Use the no form of this command to restore the default value.
Command Syntax
temperature TEMP_LOW TEMP_HIGH TEMP_CRIT
no temperature
Low alarm temperature degree Celsius, range
-15 to 50
High alarm temperature degree Celsius, range
50 to 85
Critical temperature degree Celsius, range 55
to 90
Command Mode
Global Configuration
Default
The default threshold is low temperature 5, high temperature 65, and critical temperature 80.
Usage
The unit for temperature is centigrade. The critical temperature must higher than high
temperature 5 Celsius degrees. The high temperature must higher than low temperature 5
Celsius degrees.
Examples
This example shows how to specify the temperature thresholds:
Switch(config)# temperature 5 70 80