9 Purchasable Options
The system supports the following configuration options:
Table 18: Standard Software Option Keys
Option
Description
70 kV Scan Mode Enables 70 kV scan mode.
High Definition Enables High Resolution scanning (focal spot deflection). Only available
with GE Tube.
Cardiac Scan Modes Enables Cardiac scan acquisition modes, External ECG gating and guides
the user in selecting the appropriate cardiac imaging mode based on pa‐
tient profile.
Provides retrospective review of the gating information and capability to
edit the triggering information on the ECG waveform.
ECG Gating
Enables internal ECG trigger device. Provides capability to display and
view the ECG waveform on the operator console.
Temporal Enhance Enables Temporal Enhance prescription used with Snapshot Freeze mo‐
tion correction.
Reconstruction mode to create images to support SnapShot Freeze car‐
diac image post processing.
SmartPrep with Dynamic Transition
Enables real-time monitoring of IV contrast and a user-selectable mode to
dynamically transition to the diagnostic scan phase when a user entered
Enhancement Threshold is reached in the Transition ROI.
Overlapped Recon
Overlapped image reconstruction for Axial scan type generates 512 im‐
ages from a 160mm acquisition.
Organ Dose Modulation mA profile as a function of tube angle to reduce organ specific dose.
Digital Tilt Protocols that allows prospective tilted MPR.
0.28 Sec Rotation Enables 0.28 second scanning.
256 Slice Enables up to 256 slice detector coverage, increasing coverage to 160 mm
from default of 80 mm.
3D Dose Modulation Rotational and Z-axis dose modulation.
Dynamic Perfusion Enables protocols that use multiple groups to accomplish variable sam‐
pling.
CARDIQ Xpress 2.0 Reveal Provides the user with multiple tools to post process images from cardiac
data sets.
AutoBone Xpress Facilitates removal of bone and CT table from CT Angiography (CTA)
studies of the abdomen and lower extremities.
Advanced Vessel Analysis Xpress — AVA Express Provides enhanced analysis of vascular features, which include stenosis
analysis, pre/post stent planning procedures and directional vessel tortuos‐
ity visualization.
CT Colon (CTC) Pro 3D_EC — CT Colon Pro 3D
Provides comprehensive software package for evaluation of quick, accu‐
rate, noninvasive colon exams.
CardEP Post processing image analysis software for the application of cardiovas‐
cular and electrophysiology imaging.
Volume Viewer 5.0 — Volume Viewer Provides protocols for reformat, 3D rendering and volume rendering.
CT Perfusion 4D Multi-Organ — Perfusion 4D Multi-organ package includes protocols for neuro stroke and tumor perfu‐
sion imaging and body tumor including liver perfusion imaging.
CT Perfusion 4D Neuro — Perfusion 4D Neuro Package includes protocols for neuro stroke and brain tumor perfusion.
Revolution CT User Manual
Direction 5480385-1EN, Revision 1
Chapter 8 Equipment 189