On the iBMC WebUI, the LDAP function has been enabled, a user domain has been
set, and the LDAP users who belong to the user domain have also been set. For
details, see the LDAP Settings page.
a. Select the UI language.
b. Enter the LDAP user name and password.
NOTE
To log in as an LDAP user, the user name can be in either of the following formats:
n LDAP user name (Domain is Automatic matching or a specified domain.)
n
LDAP user name@domain name (Domain must be Automatic matching.)
c. Select the LDAP user Domain from the Domain drop-down list.
NOTE
The Domain drop-down list contains the following options:
n
This iBMC: You can select this option to log in as a local user. The system
automatically uses a corresponding user from the local user list.
n
Configured domain servers: You can select a domain server to log in as an LDAP user.
The system automatically uses a corresponding user from the domain server.
n
Automatic matching: If the option is selected, the system searches the local user list
first. If a corresponding user is not found, the system searches the domain servers in
the sequence displayed in the Domain drop-down list.
d. Click Log In.
If the login is successful, the Information Summary page is displayed, showing
the user name in the upper right corner.
----End
5.5.2 Configuring the iBMC
This topic describes how to change the default password of the iBMC and set its IP address.
Scenarios
Change the default iBMC password of the G530 V2 and set its IP address to improve system
security.
NOTE
l The password complexity check function is enabled by default.
l A simple password is easy to crack, which makes the system vulnerable. You are advised to use a
password that meets complexity requirements or to enable the password complexity check function.
l To ensure system security, change your initial password at your first login and change the password
periodically.
Impact on the System
This operation has no adverse impact on the system.
Prerequisites
Conditions
l The G530 V2 is powered on.
FusionServer G5500 Server
User Guide
5 Configuring the G5500
Issue 02 (2017-12-15) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
106

Table of Contents

Other manuals for Huawei FusionServer G5500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei FusionServer G5500 and is the answer not in the manual?

Huawei FusionServer G5500 Specifications

General IconGeneral
Chassis typeRack (4U)
Device class-
Product colorBlack
Number of fans6 fan(s)
Redundant fans supportYes
AC input voltage110-240 V
80 PLUS certification80 PLUS Platinum
Number of power supply units4
Power supply unit (PSU) capacity2200 W
Storage drive capacity- GB
Storage drives installedNo
Maximum supported storage capacity- TB
USB 2.0 ports quantityUSB 2.0 ports have a data transmission speed of 480 Mbps, and are backwards compatible with USB 1.1 ports. You can connect all kinds of peripheral devices to them.
Weight and Dimensions IconWeight and Dimensions
Depth790 mm
Width447 mm
Height175 mm