Table 11-5 PSU specifications
PSU Type Input Parameter Maximum Output
Power
Power Cable
2200 W PSU
l 200 V AC to 240
V AC at 50 Hz
or 60 Hz
l 240 V DC
l One PSU: 2200
W
l Four PSUs in
2+2 redundancy
mode: 4400 W
l Two PSUs in
1+1 redundancy
mode: 2200 W
16 A power cables
complying with
IEC320 C19 and
IEC320 C20
100 V AC to 120 V
AC at 50 Hz to 60
Hz
l One PSU: 1200
W
l Four PSUs in
2+2 redundancy
mode: 2400 W
l Two PSUs in
1+1 redundancy
mode: 1200 W
11.3 Environmental Specifications
Table 11-6 describes the specifications of the G5500
Table 11-6 Environmental specifications
Item
Specifications
Temperature
l Operating temperature: 5°C to 35°C (41°F to 95°F)
l Storage temperature: -40°C to +65°C (-40°F to +149°F)
l Temperature change rate: < 20°C/h (36°F/h)
Humidity (non-
condensing)
l Operating humidity: 5% RH to 85% RH
l Storage humidity: 5% RH to 95% RH
l Long-term storage humidity: 30% RH to 69% RH
Altitude ≤ 3048 m (9999.88 ft). When the altitude is higher than 900 m (2952.8
ft), the highest operating temperature decreases by 1°C (1.8°F) as the
altitude increases by 300 m (984.24 ft). HDDs are not supported at an
altitude of over 3000 m (9842.5 ft).