EasyManuals Logo

Huawei FusionServer G5500 User Manual

Huawei FusionServer G5500
215 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #136 background imageLoading...
Page #136 background image
No. Description Definition
5 Maximum memory speed
l 2133 MT/s
l 2400 MT/s
l 2666 MT/s
6 CAS latency
l P: 15
l T: 17
7 DIMM type
l R: RDIMM
l L: LRDIMM
6.2.3.5 Memory Configuration
The G560 supports the following memory protection modes to increase its availability:
l Online spare memory: provides protection against failing or degraded DIMMs. Certain
memory is reserved as spare, and automatic failover to spare memory occurs when the
system detects a DIMM that is degrading. This prevents the system from running on
DIMMs prone to uncorrectable errors, which will cause system breakdown.
l Mirrored memory: provides maximum protection against failed DIMMs. Uncorrectable
errors in one channel are corrected by the mirror channel.
l Memory patrol: corrects errors upon detection. If these errors are not corrected promptly,
uncorrectable errors may occur.
To configure memory protection modes, access the BIOS and choose Advanced > Memory
Configuration. For details, see the HUAWEI Server Grantley Platform BIOS Parameter
Reference.
Online Spare Memory Configuration
Online spare memory provides protection against degraded DIMMs by reducing the
likelihood of uncorrected memory errors. This protection is available without any operating
system support.
Online spare memory protection dedicates one rank of each memory channel for use as spare
memory. The remaining ranks are available for OS and application use. If correctable memory
errors occur at a rate higher than a specific threshold on any of the non-spare ranks, the server
automatically copies the memory contents of the degraded rank to the online spare rank.
Mirrored Memory Configuration
Mirroring provides protection against uncorrected memory errors that would otherwise result
in server downtime. Mirroring is performed at the channel level to one memory channel pair
that can be either:
l Channel 1 data being mirrored in channel 2
l Channel 3 data being mirrored in channel 4
If an uncorrectable error is detected in the active memory channel, data is retrieved from the
mirror channel. This channel becomes the new active channel, and the system disables the
channel with the failed DIMM.
FusionServer G5500 Server
User Guide
6 Optional Part Installation
Issue 02 (2017-12-15) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
128

Table of Contents

Other manuals for Huawei FusionServer G5500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei FusionServer G5500 and is the answer not in the manual?

Huawei FusionServer G5500 Specifications

General IconGeneral
Chassis typeRack (4U)
Device class-
Product colorBlack
Number of fans6 fan(s)
Redundant fans supportYes
AC input voltage110-240 V
80 PLUS certification80 PLUS Platinum
Number of power supply units4
Power supply unit (PSU) capacity2200 W
Storage drive capacity- GB
Storage drives installedNo
Maximum supported storage capacity- TB
USB 2.0 ports quantityUSB 2.0 ports have a data transmission speed of 480 Mbps, and are backwards compatible with USB 1.1 ports. You can connect all kinds of peripheral devices to them.
Weight and Dimensions IconWeight and Dimensions
Depth790 mm
Width447 mm
Height175 mm