Figure 7-137 Installing a 12-bay NVMe drive backplane
Step 6 Install front drives.
Step 7 Install fan modules. For details, see 7.16 Installing a Fan Module.
Step 8 Install full-height full-length riser cards if they are required. For details, see 7.19
Removing the Riser Card.
Step 9 Install the air duct. For details, see 7.14 Installing the Air Duct.
Step 10 Install the chassis cover. For details, see 7.12 Installing the Chassis Cover.
Step 11 Install the RH2288H V3. For details, see 3.4 Installing the Server.
Step 12 Connect all external cables such as power and network cables. For details, see 3.5
Connecting External Cables.
Step 13 Power on the RH2288H V3. For details, see 4.1 Powering On the Server.
----End
7.57 Removing the Rear Hard Disk Backplane
Remove the backplane of the rear disks.
Procedure
Step 1 Wear an ESD wrist strap. For details, see 1 Safety Instructions.
Step 2 Determine the cabinet number and chassis number of the server, and label its
panel to prevent misoperations.
RH2288H V3 Server
User Guide 7 Replacing Parts
Issue 46 (2022-12-28) Copyright © Huawei Technologies Co., Ltd. 272