IS620P User Manual Chapter 1 Servo System Selection
- 15 -
Cable Name Cable Model
Cable
Length
(mm)
Cable Appearance
Servo drive
to PLC
communication
cable
S6-L-T02-2.0 2000
Resistor plug
for servo drive
communication
terminal
S6-L-T03-0.0 0
Servo drive
analog output
cable with loose
wire at one end
S5-L-A01-1.0 1000
10mm
1000±30mm
20mm
1.4 Regen Resistor Specications
Servo Drive Model
Braking Regen Specs
Min. Allowed
Resistance (Ω)
Max. Braking
Energy Absorbed by
Capacitor (J)
Resistance
(Ω)
Capacity
(W)
Single-phase
220 V
IS620PS1R1I - - 50 9
IS620PS1R6I - - 50 9
IS620PS2R8I - - 45 18
Single/Three-
phase 220 V
IS620PS5R5I 50 50 40 26
Three-phase
220 V
IS620PS7R6I
25 80
20 26
IS620PS012I 15 47
Three-phase
380 V
IS620PT3R5I 100 80 80 28
IS620PT5R4I 100 80 60 34
IS620PT8R4I
50 80 45
50
IS620PT012I 50
IS620PT017I
40 100
35 81
IS620PT021I
25
122
IS620PT026I 122
Models IS620PS1R6 and IS620PS2R8 are not congured with a built-in regen resistor. Use
an external regen resistor if necessary. For selecting proper external regen resistors, contact
Inovance for technical support.

Table of Contents

Other manuals for Inovance IS620P Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Inovance IS620P Series and is the answer not in the manual?

Inovance IS620P Series Specifications

General IconGeneral
BrandInovance
ModelIS620P Series
CategoryServo Drives
LanguageEnglish

Related product manuals