Chapter 7 Function Code Table IS620P User Manual
- 184 -
Group H0A: Fault and Protection
Function
Code
Parameter
Name
Setting Range Unit Default
Effective
Time
Property
Control
Mode
H0A 00
Power input
phase loss
protection
selection
0: Allow faults and
forbid warnings
1: Allow faults and
warnings
2: Forbid faults and
warnings
1 0 Immediate
During
running
-
H0A 03
Retentive at
power failure
selection
0: Disabled
1: Enabled
1 0 Immediate
During
running
-
H0A 04
Motor overload
protection gain
50–300 % 100 Immediate At stop -
H0A 08
Overspeed
threshold
0–10000 rpm 0 Immediate
During
running
PST
H0A 09
Maximum
position pulse
frequency
100–4000 kHz 4000 Immediate At stop P
H0A 10
Threshold
of position
deviation fault
1–1073741824
Encoder
unit
3145728 Immediate
During
running
P
H0A 12
Runaway
protection
selection
0: Disabled
1: Enabled
- 1 Immediate
During
running
PST
H0A 16
Position
deviation
threshold in
low-frequency
resonance
1–1000
Encoder
unit
5 Immediate
During
running
P
H0A 19
DI8 lter time
constant
0–255 25 ns 80
Power-on
again
At stop -
H0A 20
DI9 lter time
constant
0–255 25 ns 80
Power-on
again
At stop -
H0A 24
Filter time of
low-speed pulse
input pin
0–255 ns 25 ns 30
Power-on
again
At stop -
H0A 25
Filter time
constant of
speed feedback
display value
0–5000 ms 50 Immediate At stop -
H0A 26
Motor overload
shielding
0: Not shield
1: Shield
- 0 Immediate At stop -