ELECTRICAL SYSTEM
B1220, B1620, B1820, WSM
9-S28
(EU)
(13) Regulator [B1220] (With OPC Type)
Continuity Across Regulator's Terminals
1. Remove the regulator.
2. Check with a tester whether the regulator is in optimum
condition or not.
3. If the continuity is not measured as show in the table below, the
contacts of the regulator are faulty.
Q Check Table
• Use a high-resistance tester as far as possible.
9Y1210272ELS0087US0
(1) Regulator 1 : Sky Blue
2 : Black
3 : Sky Blue
4 : Green
5 : Yellow
6 : Red