Maintenance work on the carrier
7.14 Hydraulic system
13.02.2018
Maintenance manual 3 302 719 en 7 - 81
GMK6300L-1
7.14 Hydraulic system
7.14.1 Checking the oil level
Prerequisites – The truck crane must be aligned horizontally at on-road level; à Manual
de instrucciones
.
– The outriggers must be retracted;
à Manual de instrucciones.
– The engine must be switched off and secured against unauthorised
use;
à p. 2 - 3.
Checking the
oil leve
l
• Check that oil is visible in the middle of
the sight glass (1) before starting work.
If the oil level is too low
• Top up the oil; à p. 7 - 93.
O
Risk of environmental damage due to leaking consumables.
Always let consumables drain into suitable recep
tacles. Wipe up any
consumables that escape.
Store/dispose of consumables and any soaked equipment properly.
Ask about the applicable regulations.
D
S
Risk of damage to the hydraulic system
When working with hydraulic oil, cleanliness is imperative.
Even fresh hydraulic oil should be filtered.

Table of Contents

Other manuals for Manitowoc Grove GMK6300L-1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc Grove GMK6300L-1 and is the answer not in the manual?

Manitowoc Grove GMK6300L-1 Specifications

General IconGeneral
BrandManitowoc
ModelGrove GMK6300L-1
CategoryConstruction Equipment
LanguageEnglish

Related product manuals