7.19.6 Renewing the corrosion protection
Protective agent,
tools
– Spray gun with spray extension.
–Brush.
– Protective clothing, protective goggles.
Prerequisites – The undercarriage of the truck crane must be thoroughly cleaned.
– The truck crane must be raised on outriggers or parked over an
inspection pit.
–
The engine must be switched off and secured against unauthorised use;
à p. 2 - 3.
Checking At the factory, the underside of the carrier was sprayed with corrosion
protection for the first time.
The corrosion protection i
s solvent-free and is water soluble while being
sprayed on. A transparent, waxy,
protective film is formed after a drying
time of one hour.
• Check the condition of the original protective film.
• If required, remove any rust and touch up the paintwork before you
spray on a new protective film.
Processing
instructions
• Observe the processing instructions for corrosion protection:
– Processing temperature: above 10 °C (50 °F).
– Removability before drying: With water.
– Removability after drying: With solvent naphtha.
– Drying time: 1 hour.
s
M 12
Protective agent GROVE part no.
Corrosion protection
03140192

Table of Contents

Other manuals for Manitowoc Grove GMK6300L-1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc Grove GMK6300L-1 and is the answer not in the manual?

Manitowoc Grove GMK6300L-1 Specifications

General IconGeneral
BrandManitowoc
ModelGrove GMK6300L-1
CategoryConstruction Equipment
LanguageEnglish

Related product manuals