Maintenance work on the carrier
7.17 Air conditioning system
7 - 112 3 302 719 en Maintenance manual
GMK6300L-1
13.02.2018
7.17.3 Cleaning the condenser fins
• Switch the air-conditioning system off.
• Clean the condenser fins (1) with
compressed air;
à Have the radiator checked/
cleaned
, p. 7 - 17.
7.17.4 Checking the entire air-conditioning system
H
This inspection may only be performed by Manitowoc Crane Care or an
authorised GROVE dealer or an authorised specialist workshop.
• Have the entire air-conditioning system checked for leaks and proper
functioning.
The inspection of the air-conditioning system particularly includes the
inspection of
– the refrigerant collector, in accordance with the pressure container
regulations (test group
II) and
– the refrigerant compressor.
• Only allow the system to be topped up with suitable refrigerant.
S
Risk of damage to the condenser.
Do not use a high pressure cleaner or steam jet cleaner. The powerful jet
may damage the fins. Use only compressed air for cleaning.
G
Risk of burns due to escaping refrigerant.
Wear suitable safety glasses and gloves when checking the hoses and
connections.
This will prevent injury from suddenly escaping refrigerant. Seek medical
attention if the skin or eyes come into contact with the refrigerant.